Only logged in customers who have purchased this product may leave a review.
PRONK
PRONK FLOWTRAX FT-2
Spesifikasi Produk
Range: Manual : -12.5 to +75 PSI, Electronic Occlusion (IV pump Testing): 0 – 40 PSI Accuracy : 0.5% of reading +/- 1 LSD Resolution : .01 PSI Units of Measure: mmHg, PSI (G), inH20, cmH2O, kPa, atm, inHg, BAR (A), BAR (G) Flow and Volume Performance Range: 0.5 to 999 ml/hr Accuracy*: 1% of reading ± 1 LSD for 1ml/hr to 999ml/hr, 2% ± 1 LSD below 1ml/hr. 0.85% of reading for 500ml/hr, 12ml Volume under steady flow conditions. Precision Volume : ≤ 0.01ml Temperature Performance Range : -28.9 to +115.5°C Accuracy : 0.1% +/- 0.2 °C Resolution : 0.1 °C General Power : Powered by two AA (Alkaline or Lithium) cells or 6 VDC Input Battery : Alkaline: min. 3 hours (without Bluetooth), Lithium: min. 10 hours (without Bluetooth) Size (HxWxD) : 13.97 x 8.26 x 5.08 (cm)
Garansi
Ya
Satuan Barang
Unit
Berat per Produk
1.000,00 gr
Dimensi per Produk
P 0 cm x L 0 cm x T 0 cm (0 cm3)
Informasi Lainnya
untuk detail produk/pemesanan silakan hubungi : cs : 0851 7170 7770 ig : faniaersapratama www.faniaersa.com
Kelengkapan Produk
> Garansi 1 tahun, Layanan Purna Jual, 60cc Syringe, 3-way stopcock, Temperature Probe Adapter Cable, Pressure Testing Luer Connector, Cleaning Solution, Cleaning Brush, Output Hose, Power Supply, spare filters and Carrying case.
Label Produk Ramah Lingkungan Hidup
–
Lokasi Tempat Usaha
Kota Depok
Deskripsi Produk
The STANDARD FT-2 FlowTrax® IV Pump Analyzer provides the fastest, most accurate test results – within a remarkable 3 minutes. Integrated full-featured pressure & temperature meters plus digital timer saves the time and cost of buying/calibrating four devices! ● Results within 1% accuracy for rates from 1 ml/hr to 999 ml/hr in less than 3 minutes ● Quick Prime feature rapidly readies unit for use — no stopping to re-prime between tests! ● Electronic Occlusion feature ● Test any type of infusion device from PCA, syringe, volumetric to feeding pumps and more. ● Up to 40X faster than other products — requires as little as little as 0.5 ml volume for low rate tests to achieve w/in 1% accuracy ● Never miss a test result with Trend feature ● Capture real-time results to any file, form or record on your PC with DataSnap ● Market-best measurement resolution of 0.0008 milliliters ● Patent-pending dynamic fluid detection system tracks fluid movement in real-time with 1,200 measurement points in a 1-ml fluid column, yielding superior accuracy in fluid volume and rate calculations over any other analyzer.