RIGEL SafeTest60

Alat untuk menguji keamanan listrik peralatan medis

SPECIFICATION:
 
Earth Continuity
Pre-pulse 65-25A peak current, (0.1 to 0.8 Ω respectively)
Pulse shape  Exponential decay
Decay time  200 – 550ìs to 5% of peak current, (0.1 to 0.8 Ω respectively)
Method 2 wire 2 wire
Measurement Current  >± 200mADC into 2Ω
Max Test Voltage  4-24Vrms o/c
Measuring Range (low range) 0.001 – 0.999Ω
Resolution 0.001Ω
Measuring Range (mid range)  1.00 – 9.99Ω
Resolution  0.01Ω
Measuring Range (high range)  10.0 – 19.9Ω
Resolution 0.1Ω 0.1Ω
Accuracy ± 1% of value, ± 5mΩ ± 1% of value, ± 5mΩ
Circuit Protection  Test inhibited if ≥ 30VAC or DC at 4mm inputs
   
Insulation Resistance
Measurement  EUT to Earth
Voltage 500VDC @1mA 500VDC @1mA
Maximum O/C Voltage  <600VDC
Range  100K – 20MΩ ± 5% ± 2 digits
Resolution 0.01MÙ 0.01MΩ
Short circuit current <2mA <2mA
   
Powered Leakage Measurements
IEC 62353  Equipment Leakage (Direct)
IEC / AAMI 60601  Earth + Enclosure Leakage
NFPA-99  Ground + Chassis Leakage
IEC 61010  Touch Leakage, Touch Voltage
Test Voltage Mains Supply Voltage
Measuring Range  0.1- 9999μA (0.1-8000μA typical for IEC61010)
Measurement/Display Resolution  0.1μA
Accuracy  ± 2%, ± 5μA
Mains Reversal  Soft key
Single Fault Conditions  Open neutral and Open earth via soft key
Frequency Response  IEC 60601 – 62353, NFPA-99, and IEC 61010 selectable
   
Voltage measurement
Application L-N, L-E, N-E and touch voltage (IEC 61010)
Range  0.0V – 300VAC
Resolution 0.1V
Accuracy  ± 2% ± 2 digits (between 10V – 270VAC)
Mains frequency  45.0 – 66.0Hz
Resolution 0.1Hz 0.1Hz
Accuracy  Unspecified
   
EUT Load Current Measurement
Range 0.0A – 20.0A 0.0A – 20.0A
Resolution 0.1A 0.1A
Accuracy ±5% ± 2 digits ±5% ± 2 digits
 
General  
Mains power 90-264V 48-64Hz
Maximum current rating  20A @ 120V / 16A @ 230V
Duty cycle (@21°C ambient)  16A to 20A, 3 min. on/ 10 min. off
10A to 15A, 3 min. on/ 5 min. off
0A to 10A, continuous
Weight 1.1kg / 2.5lbs (unit)
  2.2kg / 5lbs (complete with accessories)
Size (L x W x D)  225 x 150 x 100mm / 9 x 6 x 4”
Operating temperature  0 to 40°C
Humidity  0 -98% Relative humidity, non-condensating
Storage temperature -10 to 50°C
Altitude 0 – 2000m 0 – 2000m
Ingress Protection IP 40
Operating pollution  degree 2, according to IEC 60529
 
 
Standard Accessories :  
Detachable mains cable  
Bond test probe with clip  
Quick start guide  
Calibration certificate  
Carrying case  

 